GENERAL

Chemical metering pumps shall be positive displacement, Liquifram™ type pumps that are UL and CUL approved. Output volume shall be adjustable while pumps are in operation from zero to maximum capacity of:

A17, A77, A97       

0.42 GPH 

( 1.6 liters per hour )

A14, A74, A94       

0.58 GPH 

( 2.2 liters per hour )

AA18, AA78           

0.75 GPH 

( 2.8 liters per hour )

AA15,AA75,AA95    

1.0   GPH 

( 3.8 liters per hour )

A16, A76, A96       

2.0  GPH 

( 7.6 liters per hour )

Chemical metering pumps shall be capable, without a hydraulically backed diaphragm, of injecting solutions against pressures up to:

AA14,AA74,AA94

250 psig

17.3 bar

AA17,AA77,AA97

140 psig

  9.7 bar

AA15,AA75,AA95

110 psig

 7.6 bar

AA18,AA78

80 psig

 5.5 bar

AA16,AA76,AA96

50psig

 3.5 bar

SERIES A1  

Adjustment shall be by means of readily accessible dial knobs, one for changing stroke length and the other for changing stroke frequency. Both knobs are to be located opposite the liquid handling end. On-off switch shall be integral with frequency control, "off" position to be below lowest frequency setting.

 SERIES A7  

Control of Series A7 metering pumps shall be selectable between internal and external pulsing by means of a switch integral with frequency control knob. "External" position to be below lowest internally paced frequency setting. Stroke length shall be adjustable by means of readily accessible dial knob. When in external pulsed mode, Series A7 units shall accept signals without the use of electrical timer or internal timer.  

SERIES A9  

Series A9 metering pumps shall have a clear liquid crystal display. Control shall be selectable between internal and external pulsing by means of a means of a tactile keypad. Internal stroke frequency shall be adjustable from 1 stroke per hour to 100 strokes per minute. Pressure capacity shall be keypad adjustable to reduce noise, vibration and wear. Metering pump shall be capable of dividing or multiplying pulse inputs from 1 to 999 or responding directly or inversely to a 4-20mA input signal.

 

DRIVE

The pump drive shall be totally enclosed with no exposed moving parts. Solid state electronic pulser shall be fully encapsulated and supplied with quick connect terminals at least 3/16" (4.75 mm) wide. Electronics shall be housed in chemical resistant enclosure at the rear of the pump for maximum protection against chemical spillage. Electrical power consumption shall not exceed 22 watts per hour under full speed and maximum pressure conditions. Pump weight shall not exceed 14 lbs (6.5 kg).  

AUTOMATIC PRESSURE RELIEF  

To eliminate need for pressure relief valve, LiquiframTM shall automatically stop pulsating when discharge pressure exceeds pump pressure rating by not more than 35%.

MATERIAL  

Chemical metering pump housing shall be of chemically resistant glass fiber reinforced thermoplastic. All exposed fasteners shall be stainless steel. Chemical metering pump valves shall be ball type, with ceramic balls1. Valve seat and seal ring shall be renewable by replacing the combination seat-seal ring2 or cartridge valve assembly. Pump head shall be of transparent acrylic3 material capable of resisting the pumped chemical. Fittings and connections at pump head shall be PVC4.

CHECK VALVES AND TUBING

 A total of 16 ft (4.8 m) of polyethylene tubing5 shall be provided per pump complete with compression connections. A foot valve with integral one piece strainer shall be provided for the suction line, and an injection check/back pressure6 valve with ½" NPT male connection for the injection point. The injection check valve shall incorporate a dilating orifice which prohibits scale formation and accumulation of crystalline deposits.